Tehničke Specifikacije
Item | S5560X-30C-EI | ||||
Port Switching capacity | 288Gbps | ||||
Box Switching capacity | 598Gbps | ||||
Packet forwarding rate | 216 Mpps | ||||
Dimensions (H × W × D) | 43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in) | ||||
Weight | ≤ 6.7 kg (14.77 lb) | ||||
Flash/SDRAM | 512MB/2GB | ||||
Management Ethernet ports | 1 | ||||
Console ports | 1 × RJ-45 console port | ||||
1 × Micro-USB console port | |||||
Only the Micro-USB console port is available when you connect both ports. | |||||
Service ports | 24 × 10/100/1000Base-T autosensing Ethernet ports (including 8 combo interfaces) | ||||
4 × 10G SFP+ ports | |||||
Expansion slots | 1 | ||||
Stacking bandwidth | Maximum 160Gbps | ||||
Compatible interface module | 2-port 40GE QSFP+ interface module | ||||
2-port 10G SFP+ interface module | |||||
2-port 10G electrical interface module | |||||
4-Port 10/100/1000BASE-T Ethernet,6-Port SFP(2-Port Combo) Interface Module | |||||
8-port 10G SFP+ interface module | |||||
8-Port 10G SFP Plus with MACSec Interface Module | |||||
8-Port 1/2.5/5G BASE-T Ethernet Copper Interface Module | |||||
8-Port 1/2.5/5/10G BASE-T Ethernet Copper Interface Module | |||||
AC input voltage | PSR150-A1&PSR150-A2: | ||||
Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz | |||||
Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz | |||||
DC input voltage | PSR150-D1: | ||||
Rated: –48 VDC to –60 VDC | |||||
Max: –36 VDC to –72 VDC | |||||
You can use a –48 VDC power source in the equipment room or an H3C RPS (RPS800-A or RPS1600-A). | |||||
Min. power consumption | Single AC input: 24 W | ||||
Dual AC inputs: 29 W | |||||
Single DC input: 24 W | |||||
Dual DC inputs: 28 W | |||||
Max. power consumption | Single AC input: 87 W | ||||
Dual AC inputs: 91 W | |||||
Single DC input: 88 W | |||||
Dual DC inputs: 95 W | |||||
MTBF(Year) | 178.67 | ||||
Operating temperature | 0ºC to 45ºC (32°F to 113°F) | ||||
-60m-5000m altitude: From 0m, the maximum operating temperature reduce by 0.33℃ for every time 100 the altitude increases by 100m. | |||||
Storage temperature | -40℃ to 70℃(-40℉ to 158℉) | ||||
Operating &storage humidity | 5% RH to 95% RH, non-condensing | ||||
SDN/OpenFlow | OpenFlow 1.3 | ||||
Multiple controllers (equal/master/slave controller role) | |||||
Concurrent processing of multiple flow tables | |||||
Group table | |||||
Meter | |||||
VXLAN | VXLAN L2 switching | ||||
VXLAN L3 routing | |||||
VXLAN VTEP | |||||
IS-IS+ENDP distributed control plane | |||||
MP-BGP+EVPN distributed control plane | |||||
OpenFlow+Netconf centralized control plane | |||||
Link aggregation | 1G/10G/40G port aggregation | ||||
Static aggregation | |||||
Dynamic aggregation | |||||
Multichassis link aggregation | |||||
Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage | ||||
Storm suppression based on PPS | |||||
Storm suppression based on BPS | |||||
Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression | |||||
Jumbo frame | A maximum of 10000 bytes | ||||
MAC address table | 64K MAC address entries | ||||
Static MAC address | |||||
Blackhole MAC address | |||||
MAC learning limit | |||||
ARP Table | ARP entries: 32K | ||||
Static entry | |||||
Gratuitous ARP | |||||
Common proxy ARP and local proxy ARP | |||||
Dynamic ARP inspection | |||||
ARP anti-attack | |||||
ARP flood suppression | |||||
ARP source suppression | |||||
ARP detection based on DHCP snooping safety entries, 802.1X entries, and IP/MAC static binding entries | |||||
VLAN | Port-based VLAN (up to 4094 VLANs) | ||||
MAC-based VLAN | |||||
Protocol-based VLAN | |||||
IP subnet based VLAN | |||||
QinQ and flexible QinQ | |||||
VLAN mapping | |||||
Voice VLAN | |||||
MVRP | |||||
Loop-free redundant Layer 2 topology | STP/RSTP/MSTP | ||||
STP Root Guard | |||||
BPDU Guard | |||||
BPDU Blocking and Root Guard | |||||
Link Detection (UDLD) | |||||
Digital Diagnostic Monitor (DDM) | |||||
G.8032 Ethernet ring protection switching (ERPS) | |||||
DHCP | DHCP client | ||||
DHCP snooping | |||||
DHCP relay | |||||
DHCP server | |||||
DHCP snooping Option 82/DHCP relay Option 82 | |||||
IRF2 | IRF2 | ||||
Distributed device management, distributed link aggregation, and distributed resilient routing | |||||
Stacking through standard Ethernet interfaces | |||||
Local device stacking and remote device stacking | |||||
Support up to 9 devices stacking | |||||
IP routing | IPv4 routing number 32K | ||||
IPv6 routing number 16K | |||||
Static routing | |||||
RIPv1/v2 and RIPng | |||||
OSPFv1/v2/v3 | |||||
BGP and BGP4+ for IPv6 | |||||
Equal-cost multi-path routing (ECMP) and policy routing | |||||
VRRP/VRRPv3 | |||||
IPv6 | Neighbor Discovery (ND) | ||||
PMTU | |||||
IPv6-Ping, IPv6-Tracert, IPv6-Telnet, and IPv6-TFTP | |||||
Manual tunnel | |||||
6to4 tunnel | |||||
ISATAP tunnel | |||||
GRE tunnel | |||||
Multicast | IGMP Snooping v1/v2/v3 and MLD Snooping v1/v2 | ||||
PIM Snooping | |||||
MLD Proxy | |||||
Multicast VLAN | |||||
IGMP v1/v2/v3 and MLD v1/v2 | |||||
PIM-DM, PIM-SM and PIM-SSM | |||||
MSDP and MSDP for IPv6 | |||||
MBGP and MBGP for IPv6 | |||||
MPLS | Support MPLS | ||||
Support MCE | |||||
Support MPLS VPN, VPLS | |||||
Mirroring | Flow mirroring | ||||
N:4 port mirroring | |||||
Local port mirroring and remote port mirroring | |||||
Policy-based Mirroring | |||||
Traffic Mirroring | |||||
QoS/ACL | Layer 2 to Layer 4 packet filtering | ||||
Traffic classification based on source MAC, destination MAC, source IP, destination IP, TCP/UDP port, and VLAN | |||||
Time range-based ACL | |||||
Bi-directional ACLs (inbound and outbound) | |||||
VLAN-based ACL issuing | |||||
Rate limit for receiving and transmitting packets (a minimum CIR of 8 Kbps) | |||||
Packet redirection | |||||
802.1p priority and DSCP priority | |||||
Committed Access Rate (CAR) | |||||
Flexible queue scheduling algorithms based on both port and queue, including SP, WRR, and SP+WRR | |||||
Security | Hierarchical user management and password protection | ||||
MAC-based authentication | |||||
802.1X | |||||
Storm constrain | |||||
Guest VLAN | |||||
AAA authentication | |||||
RADIUS authentication | |||||
HWTACACS | |||||
SSH 2.0 | |||||
Port isolation | |||||
Port security | |||||
EAD | |||||
Dynamic ARP detection | |||||
BPDU guard and root guard | |||||
uRPF | |||||
IP/Port/MAC binding | |||||
Plaintext authentication and MD5 authentication for OSPF and RIPv2 packets | |||||
Public Key Infrastructure (PKI) | |||||
IP Source Guard | |||||
IEEE | IEEE 802.3x | ||||
IEEE 802.3ad | |||||
IEEE 802.3af | |||||
IEEE 802.3at | |||||
IEEE 802.3bz | |||||
IEEE 802.1p | |||||
IEEE 802.1x | |||||
IEEE 802.1q | |||||
IEEE 802.1d | |||||
IEEE 802.1w | |||||
IEEE 802.1s | |||||
Loading and upgrading | Loading and upgrading through XMODEM/FTP/TFTP | ||||
Loading and upgrading from USB | |||||
Management and maintenance | Configuration through CLI, Telnet, and console port | ||||
SNMP v1/v2/v3 | |||||
Web network management | |||||
Remote Monitoring (RMON) alarm, event, and history recording | |||||
IMC network management system | |||||
System log, alarming based on severity, debugging information output | |||||
NTP, SNTP | |||||
Power, fan, and temperature alarming | |||||
Ping and Tracert | |||||
Virtual Cable Test (VCT) | |||||
Device Link Detection Protocol (DLDP) | |||||
LLDP, LLDP-MED | |||||
Loopback detection | |||||
Power saving | Automatic port power-down | ||||
Scheduled port power-down (schedule job) | |||||
802.3az Energy Efficient Ethernet (EEE) support | |||||
EMC | FCC Part 15 Subpart B CLASS A | ||||
ICES-003 CLASS A | |||||
VCCI CLASS A | |||||
CISPR 32 CLASS A | |||||
EN 55032 CLASS A | |||||
AS/NZS CISPR32 CLASS A | |||||
CISPR 24 | |||||
EN 55024 | |||||
EN 61000-3-2 | |||||
EN 61000-3-3 | |||||
ETSI EN 300 386 | |||||
GB/T 9254 | |||||
YD/T 993 | |||||
Safety | UL 60950-1 | ||||
CAN/CSA C22.2 No 60950-1 | |||||
IEC 60950-1 | |||||
EN 60950-1 | |||||
AS/NZS 60950-1 | |||||
FDA 21 CFR Subchapter J | |||||
GB 4943.1 |