H3C S5560S-28S-EI Ethernet Switch

Šifra: 9801A1NA
H3C S5560S-28S-EI Ethernet Switch with 24*10/100/1000BASE-T Ports and 8*100/1000BASE-X SFP Combo Ports and 4*1G/10G BASE-X SFP Plus Ports

Serija svičeva H3C S5560S-EI je robusna (modularno dvostruko napajanje) i laka za implementaciju Layer 3 komutacije, rješenje koje nudi poboljšanu bezbjednost i 10GbE uplink, BGP i Multicast, SDN i IRF, fleksibilan menadžment.
Nudi sledeće prednosti:
Bogate layer 3 funkcije sa H3C-ovim operativnim sistemom Comware 7.
Pouzdan dizajn hardvera sa modularnim dvostrukim napajanjem.
Ugrađeni SmartMC pruža najlakše i najjednostavnije rješenje za rad i upravljanje mrežom.
Ethernet portovi visokog kapaciteta 10/100/1000Base-T sa  i GE/10GE SFP + portovi
Kao pristupni uređaj na mrežama preduzeća, ovaj svič može da obezbijedi GE veze visokih performansi za desktop aplikacije.

 

Tehničke Specifikacije:

 

Item
S5560S-28S-EI
Port Switching capacity
128Gbps
Box Switching capacity
598Gbps
Packet forwarding rate
96 Mpps
CPU
1 Core, 800MHz
Dimensions (H × W × D)
43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in)
Weight
≤ 8 kg (17.64 lb)
Flash/SDRAM
512MB/512MB
Management Ethernet ports
1
Console ports
1 × RJ-45 console port
1 × Micro-USB port
Only the Micro-USB port is available if you connect both ports.
Service ports
24 × 10/100/1000Base-T autosensing Ethernet ports (including 8 combo interfaces)
4 × 10G SFP+ ports
Stacking bandwidth
80Gbps
Rated input voltage
AC: 100 VAC to 240 VAC @ 50 Hz/60 Hz
DC: –36 VDC to –72 VDC
Min. power consumption
Single 75 W AC input: 12 W
Dual 75 W AC inputs: 14 W
Single 150 W AC input: 16 W
Dual 150 W AC inputs: 22 W
Single 150 W DC input: 15 W
Dual 150 W DC inputs: 21 W
Max. power consumption
Single 75 W AC input: 33 W
Dual 75 W AC inputs: 36 W
Single 150 W AC input: 35 W
Dual 150 W AC inputs: 42 W
Single 150 W DC input: 40 W
Dual 150 W DC inputs: 47 W
MTBF(Year)
131.97
MTTR(Hour)
1
Vlan table
4K
Operating temperature
0ºC to 45ºC (32°F to 113°F)
Storage temperature
-40℃ to 70℃(-40℉ to 158℉)
Operating & storage humidity
5% RH to 95% RH, non-condensing
SDN/OpenFlow
OpenFlow 1.3
Multiple controllers (equal/master/slave controller role)
Concurrent processing of multiple flow tables
Group table
Meter
Link aggregation
1G/10G/40G port aggregation
Static aggregation
Dynamic aggregation
Multichassis link aggregation
Port features
802.3x flow control (full-duplex)
Storm suppression based on port bandwidth percentage
Storm suppression based on PPS
Storm suppression based on BPS
Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression
Jumbo frame
10
MAC address table
16K MAC address entries
Blackhole MAC address
MAC learning limit
VLAN
Port-based VLAN
MAC-based VLAN
Protocol-based VLAN
IP subnet based VLAN
QinQ and flexible QinQ
VLAN mapping
Voice VLAN
MVRP
Loop-free redundant Layer 2 topology
STP/RSTP/MSTP/PVST+/RPVST+
Smart Link
RRPP
G.8032 Ethernet ring protection switching (ERPS)
DHCP
DHCP client
DHCP snooping
DHCP relay
DHCP server
DHCP snooping Option 82/DHCP relay Option 82
IRF2
IRF2
Distributed device management, distributed link aggregation, and distributed resilient routing
Stacking through standard Ethernet interfaces
Local device stacking and remote device stacking
Support up to 9 devices stacking
IP routing
12K IPV4 routing entries
Static routing
RIPv1/v2 and RIPng
OSPFv1/v2/v3
BGP and BGP4+ for IPv6
IS-IS
VRRP/VRRPv3
IPv6
Neighbor Discovery (ND)
PMTU
IPv6-Ping, IPv6-Tracert, IPv6-Telnet, and IPv6-TFTP
Manual tunnel
6to4 tunnel
ISATAP tunnel
Multicast
IGMP Snooping v1/v2/v3 and MLD Snooping v1/v2
PIM Snooping
MLD Proxy
Multicast VLAN
IGMP v1/v2/v3 and MLD v1/v2
PIM-DM, PIM-SM, and PIM-SSM
MSDP and MSDP for IPv6
MBGP and MBGP for IPv6
Mirroring
Flow mirroring
N:4 port mirroring
Local port mirroring and remote port mirroring
OAM
802.1ag
802.3ah
QoS/ACL
Layer 2 to Layer 4 packet filtering
Traffic classification based on source MAC, destination MAC, source IP, destination IP, TCP/UDP port number, and VLAN
Time range-based ACL
Bi-directional ACLs (inbound and outbound)
VLAN-based ACL issuing
Rate limit for receiving and transmitting packets (a minimum CIR of 8 Kbps)
Packet redirection
802.1p priority and DSCP priority
Committed Access Rate (CAR)
Eight queues per port (including the CPU port)
Flexible queue scheduling algorithms based on both port and queue, including SP, WRR, WFQ, SP+WRR, and WDRR
WRED
Security
Hierarchical user management and password protection
802.1X authentication and centralized MAC address authentication
Guest VLAN
RADIUS authentication
HWTACACS authentication
SSH 2.0
Port isolation
Port security
Portal authentication
EAD
DHCP snooping
Dynamic ARP detection
BPDU guard and root guard
uRPF
IP/Port/MAC binding
Plaintext authentication and MD5 authentication for OSPF and RIPv2 packets
Public Key Infrastructure (PKI)
IP Source Guard
Management and maintenance
Loading and upgrading through XMODEM/FTP/TFTP
Configuration through CLI, Telnet, and console ports
SNMPv1/v2/v3
Web network management
Remote Monitoring (RMON) alarm, event, and history recording
IMC network management system
System log, alarming based on severity, debugging information output
NTP
Power, fan, and temperature alarming
Ping and Tracert
Virtual Cable Test (VCT)
Device Link Detection Protocol (DLDP)
LLDP, LLDP-MED
Loopback detection
Power saving
802.3az EEE
Automatic port power-down
Scheduled port power-down (schedule job)
IEEE
IEEE 802.3x
IEEE 802.3u,
IEEE 802.3z,
IEEE 802.3az,
IEEE 802.3ab,
IEEE 802.3ah
IEEE 802.3ad
IEEE 802.3af
IEEE 802.3at
IEEE 802.3bt
IEEE 802.3bz
IEEE 802.1p
IEEE 802.1x
IEEE 802.1q
IEEE 802.1d
IEEE 802.1w
IEEE 802.1s
IEEE 802.1ax
IEEE 802.1ag
EMC
FCC Part 15 Subpart B CLASS A
ICES-003 CLASS A
VCCI CLASS A
CISPR 32 CLASS A
EN 55032 CLASS A
AS/NZS CISPR32 CLASS A
CISPR 24
EN 55024
EN 61000-3-2
EN 61000-3-3
ETSI EN 300 386 for telecommunications center installations
GB/T 9254
YD/T 993
Safety
UL 60950-1
CAN/CSA C22.2 No 60950-1
IEC 60950-1
EN 60950-1
AS/NZS 60950-1
FDA 21 CFR Subchapter J
GB 4943.1