Serija svičeva H3C S5560S-EI je robusna (modularno dvostruko napajanje) i laka za implementaciju Layer 3 komutacije, rješenje koje nudi poboljšanu bezbjednost i 10GbE uplink, BGP i Multicast, SDN i IRF, fleksibilan menadžment.
Nudi sledeće prednosti:
Bogate layer 3 funkcije sa H3C-ovim operativnim sistemom Comware 7.
Pouzdan dizajn hardvera sa modularnim dvostrukim napajanjem.
Ugrađeni SmartMC pruža najlakše i najjednostavnije rješenje za rad i upravljanje mrežom.
Ethernet portovi visokog kapaciteta 10/100/1000Base-T sa i GE/10GE SFP + portovi
Kao pristupni uređaj na mrežama preduzeća, ovaj svič može da obezbijedi GE veze visokih performansi za desktop aplikacije.
Tehničke Specifikacije:
Item |
S5560S-28S-EI |
Port Switching capacity |
128Gbps |
Box Switching capacity |
598Gbps |
Packet forwarding rate |
96 Mpps |
CPU |
1 Core, 800MHz |
Dimensions (H × W × D) |
43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in) |
Weight |
≤ 8 kg (17.64 lb) |
Flash/SDRAM |
512MB/512MB |
Management Ethernet ports |
1 |
Console ports |
1 × RJ-45 console port |
1 × Micro-USB port |
|
Only the Micro-USB port is available if you connect both ports. |
|
Service ports |
24 × 10/100/1000Base-T autosensing Ethernet ports (including 8 combo interfaces) |
4 × 10G SFP+ ports |
|
Stacking bandwidth |
80Gbps |
Rated input voltage |
AC: 100 VAC to 240 VAC @ 50 Hz/60 Hz |
DC: –36 VDC to –72 VDC |
|
Min. power consumption |
Single 75 W AC input: 12 W |
Dual 75 W AC inputs: 14 W |
|
Single 150 W AC input: 16 W |
|
Dual 150 W AC inputs: 22 W |
|
Single 150 W DC input: 15 W |
|
Dual 150 W DC inputs: 21 W |
|
Max. power consumption |
Single 75 W AC input: 33 W |
Dual 75 W AC inputs: 36 W |
|
Single 150 W AC input: 35 W |
|
Dual 150 W AC inputs: 42 W |
|
Single 150 W DC input: 40 W |
|
Dual 150 W DC inputs: 47 W |
|
MTBF(Year) |
131.97 |
MTTR(Hour) |
1 |
Vlan table |
4K |
Operating temperature |
0ºC to 45ºC (32°F to 113°F) |
Storage temperature |
-40℃ to 70℃(-40℉ to 158℉) |
Operating & storage humidity |
5% RH to 95% RH, non-condensing |
SDN/OpenFlow |
OpenFlow 1.3 |
Multiple controllers (equal/master/slave controller role) |
|
Concurrent processing of multiple flow tables |
|
Group table |
|
Meter |
|
Link aggregation |
1G/10G/40G port aggregation |
Static aggregation |
|
Dynamic aggregation |
|
Multichassis link aggregation |
|
Port features |
802.3x flow control (full-duplex) |
Storm suppression based on port bandwidth percentage |
|
Storm suppression based on PPS |
|
Storm suppression based on BPS |
|
Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
|
Jumbo frame |
10 |
MAC address table |
16K MAC address entries |
Blackhole MAC address |
|
MAC learning limit |
|
VLAN |
Port-based VLAN |
MAC-based VLAN |
|
Protocol-based VLAN |
|
IP subnet based VLAN |
|
QinQ and flexible QinQ |
|
VLAN mapping |
|
Voice VLAN |
|
MVRP |
|
Loop-free redundant Layer 2 topology |
STP/RSTP/MSTP/PVST+/RPVST+ |
Smart Link |
|
RRPP |
|
G.8032 Ethernet ring protection switching (ERPS) |
|
DHCP |
DHCP client |
DHCP snooping |
|
DHCP relay |
|
DHCP server |
|
DHCP snooping Option 82/DHCP relay Option 82 |
|
IRF2 |
IRF2 |
Distributed device management, distributed link aggregation, and distributed resilient routing |
|
Stacking through standard Ethernet interfaces |
|
Local device stacking and remote device stacking |
|
Support up to 9 devices stacking |
|
IP routing |
12K IPV4 routing entries |
Static routing |
|
RIPv1/v2 and RIPng |
|
OSPFv1/v2/v3 |
|
BGP and BGP4+ for IPv6 |
|
IS-IS |
|
VRRP/VRRPv3 |
|
IPv6 |
Neighbor Discovery (ND) |
PMTU |
|
IPv6-Ping, IPv6-Tracert, IPv6-Telnet, and IPv6-TFTP |
|
Manual tunnel |
|
6to4 tunnel |
|
ISATAP tunnel |
|
Multicast |
IGMP Snooping v1/v2/v3 and MLD Snooping v1/v2 |
PIM Snooping |
|
MLD Proxy |
|
Multicast VLAN |
|
IGMP v1/v2/v3 and MLD v1/v2 |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
MSDP and MSDP for IPv6 |
|
MBGP and MBGP for IPv6 |
|
Mirroring |
Flow mirroring |
N:4 port mirroring |
|
Local port mirroring and remote port mirroring |
|
OAM |
802.1ag |
802.3ah |
|
QoS/ACL |
Layer 2 to Layer 4 packet filtering |
Traffic classification based on source MAC, destination MAC, source IP, destination IP, TCP/UDP port number, and VLAN |
|
Time range-based ACL |
|
Bi-directional ACLs (inbound and outbound) |
|
VLAN-based ACL issuing |
|
Rate limit for receiving and transmitting packets (a minimum CIR of 8 Kbps) |
|
Packet redirection |
|
802.1p priority and DSCP priority |
|
Committed Access Rate (CAR) |
|
Eight queues per port (including the CPU port) |
|
Flexible queue scheduling algorithms based on both port and queue, including SP, WRR, WFQ, SP+WRR, and WDRR |
|
WRED |
|
Security |
Hierarchical user management and password protection |
802.1X authentication and centralized MAC address authentication |
|
Guest VLAN |
|
RADIUS authentication |
|
HWTACACS authentication |
|
SSH 2.0 |
|
Port isolation |
|
Port security |
|
Portal authentication |
|
EAD |
|
DHCP snooping |
|
Dynamic ARP detection |
|
BPDU guard and root guard |
|
uRPF |
|
IP/Port/MAC binding |
|
Plaintext authentication and MD5 authentication for OSPF and RIPv2 packets |
|
Public Key Infrastructure (PKI) |
|
IP Source Guard |
|
Management and maintenance |
Loading and upgrading through XMODEM/FTP/TFTP |
Configuration through CLI, Telnet, and console ports |
|
SNMPv1/v2/v3 |
|
Web network management |
|
Remote Monitoring (RMON) alarm, event, and history recording |
|
IMC network management system |
|
System log, alarming based on severity, debugging information output |
|
NTP |
|
Power, fan, and temperature alarming |
|
Ping and Tracert |
|
Virtual Cable Test (VCT) |
|
Device Link Detection Protocol (DLDP) |
|
LLDP, LLDP-MED |
|
Loopback detection |
|
Power saving |
802.3az EEE |
Automatic port power-down |
|
Scheduled port power-down (schedule job) |
|
IEEE |
IEEE 802.3x |
IEEE 802.3u, |
|
IEEE 802.3z, |
|
IEEE 802.3az, |
|
IEEE 802.3ab, |
|
IEEE 802.3ah |
|
IEEE 802.3ad |
|
IEEE 802.3af |
|
IEEE 802.3at |
|
IEEE 802.3bt |
|
IEEE 802.3bz |
|
IEEE 802.1p |
|
IEEE 802.1x |
|
IEEE 802.1q |
|
IEEE 802.1d |
|
IEEE 802.1w |
|
IEEE 802.1s |
|
IEEE 802.1ax |
|
IEEE 802.1ag |
|
EMC |
FCC Part 15 Subpart B CLASS A |
ICES-003 CLASS A |
|
VCCI CLASS A |
|
CISPR 32 CLASS A |
|
EN 55032 CLASS A |
|
AS/NZS CISPR32 CLASS A |
|
CISPR 24 |
|
EN 55024 |
|
EN 61000-3-2 |
|
EN 61000-3-3 |
|
ETSI EN 300 386 for telecommunications center installations |
|
GB/T 9254 |
|
YD/T 993 |
|
Safety |
UL 60950-1 |
CAN/CSA C22.2 No 60950-1 |
|
IEC 60950-1 |
|
EN 60950-1 |
|
AS/NZS 60950-1 |
|
FDA 21 CFR Subchapter J |
|
GB 4943.1 |